Refined cobaltous chloride (English Version)
Technical indicators | Requirements of the 2011 version | Changes in the 2022 version | Impact analysis |
---|---|---|---|
Determination of cobalt content | Complexometric titration only | Potentiometric titration (arbitration method) added | Increase detection accuracy to ±0.1% |
Impurity control | 10 metal ions | 7 new indicators including Al/Si/P | Magnetic foreign matter ≤70μg/kg |
Detection method | Atomic absorption method is the main method | ICP-OES is uniformly adopted | Multi-element simultaneous detection |
Core parameter requirements for superior products:
Potassium hexacyanoferrate (III) oxidation system is used, and endpoint determination is achieved through a platinum-tungsten electrode system, with a relative deviation of ≤0.2%. Calculation formula:
w1 = [(V1cM - V2ρ)×10-3]/(25m/250)×100%
Recommended analysis line wavelength:
According to the "Catalogue of Hazardous Chemicals" (2015 edition):
In the preparation of lithium battery positive electrode materials: