Specification for direct current machine in ships (English Version)
Project | 2010 version | 2022 version | Range of change |
---|---|---|---|
Maximum rated voltage | 660V | 750V | +13.6% |
Working temperature rise margin | 0.85 times the test value | Allowing multi-layer winding layered assessment | Algorithm upgrade |
Vibration detection threshold | Unified standard | Introduction of full-band limit table | Graded optimization |
The new standard introduces a dynamic PID control model in the sealing of rotating parts. The test results under IP66 protection level show that the maximum leakage flow in the immersion test is reduced by 43%, which effectively copes with the high salt fog environment in the South China Sea.
The 1200-hour continuous salt spray test found that metal electroplated parts need to pay special attention to the integrity of the protective layer of the H65 brass substrate. The test data showed that the durability of the zinc-nickel alloy plating is 450% better than that of electrolytic polishing.
Frequency range | Conduction limit | Measured abnormal scenarios |
---|---|---|
10kHz-150kHz | 120dBμV | Start-stop transient exceeds limit by 76% |
500kHz-30MHz | 73dBμV | Composite shielding compliance rate is 92% |
Copyright ?2007-2025 ANTPEDIA, All Rights Reserved