Pneumatic fluid power—Compressed air pressure regulators and filter-regulators—Part 3:Alternative test methods for measuring the flow-rate characteristics of pressure regulators (English Version)
GB/T20081.3-2021 is equivalent to the ISO69533:2012 international standard, and innovatively proposes the use of isothermal gas tanks to replace the traditional flow meter test method. This method calculates the flow characteristics by measuring the pressure change of the gas tank, which is energy-saving and efficient.
Comparison dimensions | Methods in this document | ISO69532 method |
---|---|---|
Test time | Reduced to 1/10 | Conventional time |
Air consumption | Reduced to 1/30 | Full flow consumption |
Applicable flow range | Capable of measuring large flow elements | Limited by air source |
The standard stipulates that the test circuit must include:
Special note: The volume of the gas tank must satisfy the formula Vup2max>Vd(pu-p1)
Three-level smoothing is used:
qv(j)=V(p'3(j+1)-p'3(j-1))/(2Δtρ0RT3)
Appendix B shows data processing examples for three typical valve bodies (direct-acting, pilot-operated, and electro-pneumatic).
Application scenario selection:
Quality control points: